FedBizOpps banner

Login to begin searching the FBO/CBD
Home Page
CBD/FBO Online
CBD/FBO Email
About Us
Contact Us
Privacy
Categories
No. Notes
Archives
Search
Help
Login
Register

Popular Searches

Popular Categories

Real-time Prosthetics Controller, Data and Vision Acquisitio (Notice of intent to perform oral solicitation) - Attachment

General Information

Document Type:FILE
Posted Date:Nov 07, 2017
Category: General Purpose ADP Equipment Software, Supplies and Support Equipment
Set Aside:N/A

Contracting Office Address

Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662

Description

Page 3 of 3 In accordance with FAR 13.106-1 (c)(1), the Department of Veterans Affairs intends to perform oral solicitations for Real-time Prosthetics Controller, Data and Vision Acquisition System. This will be set-aside for SDVOSB s. To be considered eligible for award all SDVOSB s must be registered/verified through Vetbiz.gov. If you wish to be included in this solicitation, please respond electronically to jay.chong@va.gov by 5PM PST Friday Nov. 10th 2017. This solicitation will be performed Monday Nov. Nov.13th 2017. This will be a brand name or equal solicitation to the following Items Manufactured by National Instruments: PX5373835 PXI System Configuration PX5373835 1 Each 960680-300 Parts Repair Coverage 1 Each 782143-01 Basler ace camera, acA2000-340kc 1 Each 784592-01 12mm, 1000mm-Infinity Primary WD, High Res Fixed FL Lens 1 Each. 199745-05 Cable, Power over Camera Link(PoCL), MDR to SDR, 5M 2 Each 782055-01 Tripod Adapter Plate, Basler ace Series 1 Each 782349-01 Servo Drive, AKD-P02406-NBEC-0000, 24A, 120/240Vac, EtherCAT 2 Each 781529-03 VF-DA0474N-03 Smart Feedback Cable, AKM Motor to AKD Drive, 3m 1 Each 782683-03 VP-508DEAN-03 20A Power Cable, AKM Motor to AKD Drive, 3m 1 Each To be considered technically acceptable, the products must meet the following minimum salient characteristics: Real-time Prosthetics Controller, Data and Vision Acquisition System: Real-time Embedded Controller An embedded controller that can execute custom LabVIEW software in real-time at very high loop rates High performance CPU: 8 or more cores, Intel Xeon, 2.3 GHz or better Ultra-high system bandwidth: 24 GB/sec or higher Ultra-high per slot bandwidth: 8 GB/sec or higher Large and fast memory, 24 GB DDR 1866 MHz RAM or better Ultra-fast hard drive data storage, 800 GB SATA SSD or better Integrated DC Servo Motor Control System (Motor Drive) Can communicate and control two Kollmorgan AKM brushless DC servo motors 24 Amps, 120/240VAC EtherCAT connectivity, communication and control Integrated Data Acquisition Module 32 or more analog inputs 2 M Samples/sec 1-channel or more 1 M Samples/s multichannel or more 16-bit or higher resolution 10 V input voltage 48 or more digital input output lines (32 hardware-timed up to 10 MHz) Four or more 32-bit counter/timers for PWM, encoder, frequency, event counting Integrates with LabVIEW software Integrated Analog Output Module 4 or more channels 1 M samples/sec or greater maximum update rate 8 or more (5 V TTL/CMOS) digital I/O lines Digital triggering and external clocking 2 up/down counter/timers, 24-bit resolution Integrates with LabVIEW software Integrated Digital Input Output Module 96 or more bidirectional digital I/O lines, 5 V TTL/CMOS (line direction selectable on an 8-bit port basis) High-current drive (24 mA sink or source) Programmable DO power-up states DIO watchdogs, change detection, programmable input filters Integrates with LabVIEW software Integrated Machine Vision Camera System 2048 x 1088 resolution camera or better 340 frames per second capture or better Color Compatible with power over camera link Can be controlled with LabVIEW software Integrated Image Acquisition Module Fully programmable with custom software. Can power cameras through PoCL-enabled cables. Supports Camera Link 1.2 standard at base, medium, full, and extended full configuration. Connects to two or more cameras. Can be triggered in software. Supports up to 10-tap, 80-bit acquisition at 20 to 85 MHz pixel clock frequency 850 MB/s of bandwidth over two Camera Link cables Power over Camera Link (PoCL) support; Can be used with PoCL cables to power cameras or without I/O includes 4 TTL, 2 optoisolated inputs, 1 quadrature encoder Integrates with LabVIEW software Integrated Simultaneous Strain Gauge Bridge Input Module 8 or more simultaneously sampled analog input channels 25 k Samples/sec/ch sampling rate or better 24-bit ADC per channel; antialias filtering Software-selectable excitation voltage per channel (0.625 V to 10 V) Built-in programmable quarter-, half-, and full-bridge completion and shunt calibration per channel Multidevice triggering and synchronization Integrates with LabVIEW software Integrated High Speed Data Storage Module Four drive, HDD, 4TB or more integrated storage, SATA 3.0 interface Integrates with LabVIEW software and all the above-mentioned modules. Must be compatible with National Instruments LabVIEW software, which we currently have, to maintain compatibility with existing devices that will interface with the proposed system. Vendor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system such that OEM warranty and service are provided and maintained by the OEM. All software licensing, warranty, and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. This procurement is for new Equipment ONLY; no remanufactured or "gray market" items. All Equipment must be covered by the manufacturers warranty. *This notice satisfies the requirement at FAR 5.201 to synopsize proposed contract actions. *

Original Point of Contact

POC Jay Chong

Place of Performance

Link: FBO.gov Permalink
Link: FBO.gov Permalink
Bookmark This Notice
Print View