FedBizOpps banner

Login to begin searching the FBO/CBD
Home Page
CBD/FBO Online
CBD/FBO Email
About Us
Contact Us
Privacy
Categories
No. Notes
Archives
Search
Help
Login
Register

Popular Searches

Popular Categories

CGC SAGINAW A/C CONDENSER - FAR CLAUSES

General Information

Document Type:PRESOL
Posted Date:Nov 07, 2017
Category: Ships and Marine Equipment
Set Aside:N/A

Contracting Office Address

Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC), 2401 Hawkins Point Road, Building 31, Mail Stop 26, Baltimore, Maryland, 21226-5000, United States

Description

FAR CLAUSES U.S. COAST GUARD IS SOLICITING QUOTES FOR THE FOLLOWING: TECHNICAL SERVICES FOR INCINERATOR REPAIR ONBOARD THE USCGC SAGINAW 1. Background. This requirement is for the replacement of both A/C condensers. Its an 8 TON WATER CHILLER & RHEEN DAE - F3243, the condensers that they will be installing are: PT# MSE750Z model MSE750 CRN OH11802.5 2. Scope. The scope of this work is on the USCGC SANINAW and consists of replacing BOTH A/C condensers. 3. Objective. The objective of this requirement is to dissemble and replace both ships A/C consdensors. 4. Tasks. The contractor shall provide onboard engineering services to replace the front main oil seal include but are not limited to: 4.1. Recover refrigerant from both a/c circuits on SAGINAW. 4.2. Disconnect and remove two condensers from a/c skid in aft machinery space. 4.3. Replace with furnished condensers and put them in location where old condensers were removed. 4.4. Supply and install copper refrigerant pipe and fittings to connect both new a/c condensers to their respective refrigerant lines, where they were cut for condenser removal and install. 4.5. Remove old, and supply and install new filter drier in each a/c refrigerant circuit. 4.6. Pressurize and check a/c compressor skid for refrigerant leaks. 4.7. Put recovered refrigerant back into a/c system, energize and test system for proper operation. 5. Delivery. Contractor shall provide a final report within 3 days of contract period of performance. 6. Government furnished property. 02 A/C condensors. 7. Security Requirement. Base access is required. Vendor shall have a valid drivers license and show identification. A CG representative from the cutter will sponsor and escort vendor to the cutter. 8. Place of performance- CG SANINAW Home Prot 1500 15th St. Mobile, AL. 9. Period of performance-04DEC17-08DEC17.

Original Point of Contact

POC Mayra C. Centurion, Phone: 5106375987

Place of Performance

Address:
CGC SAGINAW, SOUTH BROAD ST, Alabama, 36615, United States
36615,
Link: FBO.gov Permalink
Bookmark This Notice
Print View